DINTEK PowerMAX500 4P Cat.6 U/FTP 23AWG PVC Indoor Box Cable - Gray
DINTEK PowerMAX500TM shielded Cat.6 / Class E U/FTP PVC cable is
guaranteed to exceed Cat.6 specifications as set down in ANSI/TIA and
ISO/IEC standards. Our PowerMAX500TM solution comprises shielded Cat.6
component compliant patch panels, keystones, and patch cords.
When combined with DINTEK’s shielded Cat.6 / Class E U/FTP PVC cable, an
end-to-end channel exists that maximizes data throughput and provides
headroom for future technologies operating to, and beyond Gigabit
Application
Horizontal and backbone cable
1000BASE-TX Gigabit Ethernet / 1000BASE-T Gigabit Ethernet
100BASE-TX Fast Ethernet / 10BASE-TX Ethernet
100 Mbps TP-PMD / 100VG-AnyLAN
Broadband Video / Voice / T1 / ISDN
10Gbit (500Mhz) Transmission up to length of 70Mtrs
DINTEK Cat6 Cable Features
Capable of handling the latest versions of Power over Ethernet
Conductor sizes for PowerMAX500TM Cat.6 set at 23AWG
PVC jacketed 4 pair telecommunications cable
Successful transmission at 500Mhz up to a length of 70Mtrs
EZI-Pull 305Mtr Reel for trouble free installation
Foil wraps act to prevent crosstalk between twisted pairs
Technical Specifications
Standards Conformance
Performance - ANSI/TIA 568.2-D Cat.6 / ISO/IEC 11801
Structural - EN 13501-6:2014 | IEC 61156-5 | EN 50288-5-1
PoE capability - IEEE 802.3bt level 3 & 4 (PoE++ & 4PPoE)
Environmental - Conforms to RoHS and REACH Directives
Flame testing - EN 60332-1-2
Construction - Conductor
Material -Pure Annealed Copper
Wire Size - 23AWG
Strand Type - Solid Core
No. Of Pairs - 4P
Insulation
Material - Polyethylene
Thickness - 0.40mm ± 0.03mm
Diameter - 1.35mm ± 0.1mm
Colors - Blue/White | Orange/White | Green/White | Brown/White
Pair Foil Wrap - Aluminum-mylar tape with tinned copper drain
Jacket
Material - PVC
Thickness - 0.5 mm ± 0.05mm
Diameter - 6.60mm ± 0.3mm
Color - Gray
Jacket Rating - CM
Foil Shield - None
Braided Shield - None
Physical Ranges - Jacket
Cold Bend Test -20 ± 2°C x 4hrs no crack
Min. Bending Radius - Min. 8 x Cable Diameter
Max. Pulling Tension - 110N
Installation Temperature - 0°C to +50°C
Operating Temperature -20°C to +60°C
Electrical
Conductor Resistance - Max. 9.38 Ω/100m at 20°C
DC Resistance Unbalance - Max. 2% at 20°C
Pair-to-Ground Capacitance Unbalance - Max. 1600 pF/km at 1 kHz
Dielectric Strength of Insulation - DC 1 KV for 1 min
Insulation Resistance Test (500V) - Min. 5000 MΩ/Km at 20°C
Mutual Capacitance - Max. 5600 pF/100m at 1 kHz
Impedance 1~250MHz - 100Ω ± 5%
Nominal Velocity Of Propagation - 78%